Error Code Potential Issue(s) Resolution(s)
Parameter storage access
failure, system halt
The second CF card error.
Once this case happens, back
up the machining data of user to
new CF card and then replace
the second CF card.
Machining data loss, re-
calibrate machining
1. Shut down controller or power
when controller state is busy.
2. The second CF card error.
3. File REGISTRY.DAT is
damaged.
Once this case happens, back
up the machining data of user to
new CF card, and then replace
the second CF card.
I/O transmission error
1. Motherboard is too hot.
2. PIO5 error
3. Motherboard error
4. Ground wire of controller is
interfered.
1. Check whether the fan turns
correctly.
2. Change the PIO5.
3. Change the motherboard.
4. Check whether the machine
touches the ground
properly.
Permanent storage data CRC
check failure, re-calibrate
before machining
1. PIO5 error
2. Fram CRC error
3. Fram doesn’t initialize
1. For the first and the second
reason, change PIO5.
2. For the third reason, using
software version which is
from 10.112.95 or 10.114.29
on.
Low memory, memory space
is less than 1M
Users design too many texts and
pictures when they design CE
human-machine interface and
make the capacity of system
memory less than 1M.
Human-machine interface of
controller should simplify
components, only design
effective variables and scripts to
avoid the low memory
phenomenon.