SmartShop|Maker Owner’s Manual
45
Error Code Potential Issue(s) Resolution(s)
NC Vile name is different with
backup name, re-calibrate
before machining
1. The system drove that writing
registry.dat and registry.mir are
written unsuccessfully leads to
two (2) file names inconsistent.
2. Install or replace registry .dat
file.
3. Rename file name when
downloading file.
1. Scan CF card disk.
2. Reselect machining file
name.
3. Check whether machining
date setting is correct.
4. Reboot.
Use last known data, re-
calibrate before machining
CF card is damaged, so
registry.dat and regisrty.mir files
are also damaged.
1. Scan CF card disk.
2. Try setting again or check
whether machining data
setting is correct.
3. Reboot.
Machine data rebuild, re-
calibrate before machining
1. Replace CF card.
2. Format CF card.
1. Reset machining data.
2. Reboot.
Power break in machining, re-
calibrate before machining
Discontinue power in machining
process.
1. Scan CF card disk.
2. Check whether machining
data setting is correct.
3. Reboot.
Machine data file write fail, re-
calibrate before machining
1. CF card is damaged.
2. Registry.dat or registry.mir files
are set read-only.
3. System file cannot handle
system resource, lead to
writing file unsuccessfully.
1. Scan CF card.
2. Check whether machining
setting is correct.
3. Reboot.