6300 Rev H User’s Manual
125-9106A Page 81
APPENDIX B : SPECIFICATIONS
Static Output
Units Feet, meters, inHg, mbar, psi, mmHg, kpa
Pressure function
range: 1 to 32 inHg
resolution: 0.001 inHg
accuracy: 0.002 inHg
Altitude function
range: -2000 ft. to 60,000 ft.
resolution: 1 foot
accuracy: 2 ft. @ 0 ft.
3 ft. @ 10,000 ft.
4 ft. @ 20,000 ft.
6 ft. @ 35,000 ft.
12 ft. @ 50,000 ft.
Climb function
range: 0 ft/min to 15,000 ft/min
resolution: 1 ft/min
accuracy: 1% of rate of climb
Pitot Output
Units knots, Mach, kmph, mph, PtinHg, QcinHg, Ptmbar, Qcmbar,
Ptpsi, Qcpsi, PtmmHg, QcmmHg, Ptkpa, Qckpa, EPR
Pressure function
range: 0 to 30 inHg (diff.)
resolution: 0.001 inHg
accuracy: 0.003 inHg
Airspeed function
range: 0 to 690 knots
resolution: 0.1 knots
accuracy: 1.0 knots @ 20 knots
0.3 knots @ 50 knots
0.2 knots @ 100 knots
0.1 knots @ 200 knots
0.04 knots @ 500 knots
Airspeed rate: 0 to 500 knots/min
Mach function
range: 0.0 to 3.0 Mach
resolution: 0.001 Mach
accuracy: 0.001 above 0.2 Mach
EPR function
range: 0.9 to 30
resolution: 0.001
accuracy: 0.002 typ.
Power requirement: 90-260 VAC, 47-440 Hz., 100W (200W with heaters).
Optional Internal battery: 8 hours of operation
Interfaces: WiFi, RS232 ; Encoder optional
Dims & weights: Main unit: 22” x 14” x 9” / 34 lbs
Remote unit: 6” x 6” x 1” / 1.8 lb.
Environmental specs: Operating temp. 0
o
to 50
o
C ; -40
o
to 50
o
C (with heaters)
Storage temp. -40
o
to 75
o
C
Humidity: 5 to 100%