6300 Rev H User’s Manual
125-9106A Page 80
APPENDIX A : ERROR CODES
Error code Description
1 Pitot Actual value exceeds knots limit or Mach limit
2 Pitot Rate Actual value exceeds knots/min limit
3 Static Actual value exceeds Feet limit
4 Static Rate Actual value exceeds Feet/min limit
5 Pitot control transducer error
6 Static control transducer error
7 Pitot leak-rate exceeds 50 knots/min; automatically returns Pitot to control
8 Static leak-rate exceeds Static Rate target; automatically return Static to control
9 Knots limit will soon be exceeded in Leak mode; returned to control mode
10 Warning: Loss of AC power. Operating on battery
11 Loss of data from Pitot or Static transducer
12 Pitot target exceeds knots limit
13 Pitot target exceeds Mach limit
14 Pitot Rate target exceeds knots/min limit (or 30 inHg/min for pressure units)
15 Static target exceeds Feet limit
16 Static Rate target exceeds Feet/min limit (or 30 inHg/min for pressure units)
17 Leaving Pitot in Measure mode may cause knots limit to be exceeded
18 Leaving Pitot in Measure mode may cause Mach limit to be exceeded
19 Serial interface error: invalid command or invalid value or syntax error
20 Calibration incomplete (Status code returned after CC command)
21 Pitot calibration complete (Status code returned after CC command)
22 Static calibration complete (Status code returned after CC command)
23 Both Pitot & Static calibration complete (Status code returned after CC command)
24 Password not set (either for Limits or Calibration)
25
Cannot enter Calibration unless Pitot is in QcinHg and Measure mode, and Static is in
inHg and Measure mode