Table 6. Configurations with one processor, under 25°C (continued)
Processor configuration
Conditionally supported
components
Commonly supported
components
One OCP module with 2 ports
Table 7. Configurations with two processors, under 25°C
Processor configuration
Conditionally supported
components
Commonly supported
components
Two processors with up to 205-
watt TDP
Processor 1 with standard heat
sink
Processor 2 with performance
heat sink
One PCIe adapter with 2 ports
One OCP module
Up to sixteen 64 GB RDIMMs
Up to two E3.S 1T drives
Up to two M.2 drives
One PCIe Ethernet adapter
One OCP module with 2 ports
One GPU adapter
One OCP module
Environment
Environment
ThinkSystem SD530 V3 complies with ASHRAE Class A2 specifications. System performance may be impacted when
operating temperature is outside AHSRAE A2 specification.
Depending on the hardware configuration, SD530 V3 also complies with ASHRAE Class H1 specification. System
performance may be impacted when operating temperature is outside ASHRAE H1 specification.
Air temperature:
Operating
ASHRAE Class A2: 10°C to 35°C (50°F to 95°F); the maximum ambient temperature decreases by 1°C for
every 300 m (984 ft) increase in altitude above 900 m (2,953 ft).
ASHRAE Class H1: 5°C to 25°C (41°F to 77°F); the maximum ambient temperature decreases by 1°C for every
300 m (984 ft) increase in altitude above 900 m (2,953 ft).
Server off: 5°C to 45°C (41°F to 113°F)
Shipment/storage: -40°C to 60°C (-40°F to 140°F)
Maximum altitude: 3,050 m (10,000 ft)
Relative Humidity (non-condensing):
Operating
ASHRAE Class A2: 8% to 80%; maximum dew point: 21°C (70°F)
ASHRAE Class H1: 8% to 80%; maximum dew point: 17°C (62.6°F)
Shipment/storage: 8% to 90%
Particulate contamination
Attention: Airborne particulates and reactive gases acting alone or in combination with other environmental factors
such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and
gases, see
“Particulate contamination” on page 15.
Note: The server is designed for standard data center environment and recommended to be placed in industrial data
center.