Server model: eight 2.5-inch SAS/SATA drives, eight 2.5-inch NVMe drives, the rear hot-swap drive
assembly, three 8i RAID adapters, one NVMe switch adapter
Notes:
The cable routing illustration is based on the scenario that the rear hot-swap drive assembly is installed.
Depending on the model, the rear hot-swap drive assembly and the 8i RAID adapter on PCIe slot 6 might
not be available on your server.
Depending on the model, if the NVMe switch adapter is installed on PCIe slot 1, route the NVMe signal
cable along the right side of the chassis.
Figure 35. Cable routing for server models with eight 2.5-inch SAS/SATA drives, eight 2.5-inch NVMe drives, the rear hot-
swap drive assembly, three 8i RAID adapters, and one NVMe switch adapter
Cable From To
1 Power cable for front backplane 1 Power connector on front backplane
1
Backplane power connector 1 on the
system board
2 SAS signal cable for front
backplane 1
SAS 0 and SAS 1 connectors on front
backplane 1
C0 and C1 connectors on the 8i RAID
adapter installed on the RAID adapter
slot
3 NVMe signal cable for front
backplane 1
NVMe 0, NVMe 1, NVMe 2, and
NVMe 3 connectors on front
backplane 1
NVMe 0–1 and NVMe 2–3 connectors
on the system board
4 NVMe signal cable for front
backplane 2
NVMe 0, NVMe 1, NVMe 2, and
NVMe 3 connectors on front
backplane 2
C0, C1, C2, and C3 connectors on
the NVMe switch adapter installed on
PCIe slot 5
50 ThinkSystem SR650 Maintenance Manual