Server model: twenty-four 2.5-inch SAS/SATA drives, the rear hot-swap drive assembly, one 8i RAID
adapter, one 24i RAID adapter
Figure 41. Cable routing for server models with twenty-four 2.5-inch SAS/SATA drives, the rear hot-swap drive assembly,
one 8i RAID adapter, and one 24i RAID adapter
Cable
From To
1 Power cable for front backplane 1 Power connector on front backplane
1
Backplane power connector 1 on the
system board
2 SAS signal cable for front
backplane 1
SAS 0 and SAS 1 connectors on front
backplane 1
C0 and C1 connectors on the 8i RAID
adapter installed on the RAID adapter
slot
3 SAS signal cable for front
backplane 2
SAS 0 and SAS 1 connectors on front
backplane 2
C0 and C1 connectors on the 24i
RAID adapter installed on PCIe slot 5
4 Power cable for front backplane 2 Power connector on front backplane
2
Backplane power connector 2 on the
system board
5 Power cable for front backplane 3 Power connector on front backplane
3
Backplane power connector 3 on the
system board
Chapter 2. Server components 59