EasyManua.ls Logo

Lenovo ThinkSystem SR860 - Page 111

Lenovo ThinkSystem SR860
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 63. Installing a PHM
a. Align the triangular marks and guide pins on the processor socket with the PHM; then, insert
the PHM into the processor socket.
Attention: To prevent damage to components, make sure that you follow the indicated
tightening sequence.
b. Fully tighten the Torx T30 captive fasteners in the installation sequence shown on the heat-sink
label. Tighten the screws until they stop; then, visually inspect to make sure that there is no
gap between the screw shoulder beneath the heat sink and the processor socket. (For
reference, the torque required for the nuts to fully tighten is 1.4 –1.6 newton-meters, 12 –14
inch-pounds).
After installing the PHM option:
1. If there are memory modules to install, install them. See
“Install a memory module” on page 104.
2. Reinstall the system board air baffle (see
“Install the system board air baffle and the power interposer”
on page 110
) or processor and memory expansion tray and processor and memory expansion tray air
baffle (see
“Install the processor and memory expansion tray on page 112).
3. Install the top cover (see
“Install the top cover” on page 128).
4. Reconnect the power cords and any cables that you removed.
5. Power on the server and any peripheral devices.
Chapter 3. Server hardware setup 103

Table of Contents

Other manuals for Lenovo ThinkSystem SR860