• Touch the static-protective package that contains the component to any unpainted metal surface on the
server; then, remove it from the package and place it on a static-protective surface.
• Make sure the type of drives to be installed is supported. Following are the types supported:
– 3.5-inch simple-swap hard-disk drive or solid-state drive in drive bay 1 and drive bay 3
– 2.5-inch simple-swap solid-state drive in drive bay 2
For a complete list of supported optional devices for the server, see
https://static.lenovo.com/us/en/
serverproven/index.shtml
.
• If there are more than one drives to be installed, determine installation order based on the following rules:
– Start with solid-state drives, and proceed with hard-disk drives.
– When installing one 3.5-inch solid-state drive and one 3.5-inch hard-disk drive, install the solid-state
drive in bay 1 and the hard-disk drive in bay 3.
– Start with the drive with the lowest capacity.
– Start with bay 1, proceed to bay 2, and bay 3.
Note: Drives of different types and different capacities are allowed to be installed in one server, but not in
the same RAID array. The drives in a single RAID array must be the same type and the same capacity. See
https://sysmgt.lenovofiles.com/help/topic/LXPML/RAID_setup.html for more details.
Watch the procedure
A video of this procedure is available at YouTube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
AU3iY3F7lq3qfqr5caGbIu
.
Procedure
Note: To prevent from damaging the drive with static discharge, do not touch the circuit board on the
bottom of the drive.
Figure 49. Circuit board on the drive
Step 1. Install the 3.5-inch drive to the drive cage.
a.
Slightly tear both sides of the retainer apart.
Note: Position the drive connectors on the opposite side of the retainer handles.
b.
Align the four holes on the drive with the corresponding pins on the retainer; then, fit the
drive into the retainer.
c. Slide the drive into the drive cage.
Chapter 3. Server hardware setup 67