Technical data
Rated data
Operation at rated mains voltage 400 V
4
31
EDS84ABD302 EN 4.0
Output currents [A] at switching frequency
2kHz 4kHz 8kHz 16 kHz
Type I
aN2
I
aM2
I
aN4
I
aM4
I
aN8
I
aM8
I
aN16
I
aM16
E84AVBxx3714 1.3 2.3 1.3 2.3 1.3 2.3 0.9 1.8
E84AVBxx5514 1.8 3.2 1.8 3.2 1.8 3.2 1.2 2.4
E84AVBxx7514 2.4 4.2 2.4 4.2 2.4 4.2 1.6 3.2
E84AVBxx1124 3.2 5.6 3.2 5.6 3.2 5.6 2.1 4.2
E84AVBxx1524 3.9 6.8 3.9 6.8 3.9 6.8 2.6 5.2
E84AVBxx2224 5.6 9.8 5.6 9.8 5.6 9.8 3.7 7.4
E84AVBxx3024 7.3 12.4 7.3 12.4 7.3 12.4 4.9 9.8
I
aNx
Rated value - continuous output current
I
aMx
Maximum output current (overload current)
z Periodic load change of 3 s with I
aMx
and recovery time of 12 s with 75 % I
aNx
z Can be achieved with the setting ”x kHz fixed/...” in C00018
Switching
frequency
When the maximum heatsink temperature is reached, the switching frequency
is reduced to 4 kHz.
With the setting ”x kHz var./...” in C00018, the switching frequency is reduced
dynamically.
z At 16 kHz and Ia > 100 % x IaN8 to 8 kHz
z At8kHzandIa>150%xIaN8to4kHz
Rated data for internal brake chopper
Switching threshold V
BRmax
: 725 V, adjustable
R
Bmin
[Ω]
I
BRmax
[A]
P
BRmax
[kW]
I
BRd
[A]
P
Bd
[kW]
t
Z
[s]
t
on
[s]
t
fp
[s]
Type
E84AVBxx3714 390
1.9 1.3 1.9 1.3 - -
E84AVBxx5514 390 1.9 1.3 1.9 1.3 - -
E84AVBxx7514 390 1.9 1.3 1.9 1.3 - -
E84AVBxx1124 180 4.0 2.9 4.0 2.9 - -
E84AVBxx1524 180 4.0 2.9 4.0 2.9 - -
E84AVBxx2224 150 4.8 3.5 4.8 3.5 - -
E84AVBxx3024 100 7.3 5.3 7.3 5.3 - -
R
Bmin
Minimum brake resistance, nominal value ±10 %
I
BRmax
Peak current
P
BRmax
Peak braking power
I
BRd
Continuous current RMS - important for cable dimensioning
P
Bd
Continuous braking power
t
Z
Cycle time, periodic load change with running time and recovery time
t
on
Running time in a cycle without reducing the scanning ratio (= no time limit)
t
Z
-t
on
Recovery time
t
fp
Maximum running time without initial load and observing the recovery time