5.12 Parameterize controller
5.12.1 General informaon on parameter seng
The controller can be parameterized in individual funcons. The basic structure of the
parameters is described in the following. The parameter list of the device is only available
aer the PLC program has been compiled. This list can be found as a tab under the controller
in the PLC project tree of the »PLC-Designer«.
Certain device commands or sengs which might cause a crical state of the
drive behavior can only be carried out when the device is disabled.
5.12.1.1 Addressing of the parameters
Each parameter features a 16-bit index as its address. Under this address, the parameter is
stored in the object directory of the device.
Parameters that belong together funconally are combined in a data set. These
parameters are addionally provided with an 8-bit subindex.
The colon is used as a separator between the index and subindex Example: "0x2540:001"
There are parameter sengs that can be changed, and (diagnosc) parameters that can
only be read.
5.12.1.2 Structure of the parameter descripons
The parameter descripons in this documentaon are structured in table form.
The representaon disnguishes parameters with a seng range, text, selecon list, and
bit-coded display.
The default seng of parameters with a write access feature is shown in bold.
Example: parameters with a seng range
Address Name / seng range / [default seng] Informaon
Index:Subindex Parameter designaon
Minimum value ... [default seng] ... maximum value
Oponal informaon with regard to the parameter.
Explanaons & notes with regard to the parameter.
Example: parameters with a selecon list
Address Name / seng range / [default seng] Informaon
Index:Subindex Parameter designaon
Oponal informaon with regard to the parameter.
Explanaons & notes with regard to the parameter.
Note: The corresponding selecon number (here 0, 1, or 2) must be set.
Other values are not permissible.
0 Designaon of selecon 0 Oponally: Explanaons & notes with regard to the corresponding
selecon.
The default selecon is shown in bold.
1 Designaon of selecon 1
2 Designaon of selecon 2
Example with bit coded display
Address Name / seng range / [default seng] Informaon
Index:Subindex Parameter designaon
Oponal informaon with regard to the parameter.
Explanaons & notes with regard to the parameter.
Bit 0 Designaon of bit 0 Oponally: Explanaons & notes with regard to the corresponding bit.
Bit 1 Designaon of bit 1
Bit 2 Designaon of bit 2
... ...
Bit 15 Designaon of bit 15