Process data transfer
Lenze device control
Process output data configuration
7
l
39
EDS82ZAFPC201 EN 4.0
FIF-CTRL1
FIF-CTRL2
Byte 2
Byte 1
Byte 3
Byte 4
FIF-CTRL.B0
FIF-CTRL.B1
FIF-CTRL.B2
FIF-CTRL.B4
FIF-CTRL.B5
FIF-CTRL.B6
FIF-CTRL.B7
FIF-CTRL.B8
FIF-CTRL.B9
FIF-CTRL.B12
FIF-CTRL.B13
FIF-CTRL.B14
FIF-CTRL.B15
FIF-CTRL.B10
FIF-CTRL.B11
FIF-CTRL.B3
DCTRL
QSP
NSET1-JOG1/3
NSET1-JOG2/3
DCTRL1-CW/CCW
DCTRL1-QSP
NSET1-RFG1-STOP
NSET1-RFG1-0
MPOT1-UP
MPOT1-DOWN
DCTRL1-CINH
DCTRL1-TRIP-SET
DCTRL1-TRIP-RESET
DCTRL1-PAR2/4
DCTRL1-PAR3/4
MCTRL1-DCB
DCTRL1-H/RE
DCTRL1-CW/QSP
DCTRL1-CCW/QSP
DFIN1-ON
PCTRL1-I-OFF
PCTRL1-OFF
PCTRL1-STOP
FIF-CTRL.B16
FIF-CTRL.B17
FIF-CTRL.B18
FIF-CTRL.B19
FIF-CTRL.B20
FIF-CTRL.B21
FIF-CTRL.B22
FIF-CTRL.B23
FIF-CTRL.B24
FIF-CTRL.B25
FIF-CTRL.B26
FIF-CTRL.B27
FIF-CTRL.B28
FIF-CTRL.B29
FIF-CTRL.B30
FIF-CTRL.B31
DCTRL
CINH
TRIP-SET
TRIP-RESET
FIF-IN.W2
FIF-IN.W3
FIF-IN.W4
FIF-IN.W1
Byte 29,30
Byte 31,32
Byte 23, 24
Byte 21, 22
Byte 19, 20
Byte 17, 18
Byte 15, 16
Byte 13, 14
Byte 11, 12
Byte 9, 10
Byte 7, 9
Byte 5, 6
NSET1-N1
NSET1-N2
PCTRL1-NADD
PCTRL1-SET1
PCTRL1-ACT
MCTRL1-MSET
RESERVED
RESERVED
RESERVED
MCTRL1-VOLT-ADD
MCTRL1-PHI-ADD
FIF-RESERVED
FIF-IN.W1
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
16 bits
C0410/1 = 200
C0410/2 = 200
C0410/3 = 200
C0410/4 = 200
C0410/5 = 200
C0410/6 = 200
C0410/7 = 200
C0410/8 = 200
C0410/9 = 200
C0410/10 = 200
C0410/11 = 200
C0410/12 = 200
C0410/13 = 200
C0410/14 = 200
C0410/15 = 200
C0410/17 = 200
C0410/18 = 200
C0410/19 = 200
C0410/20 = 200
C0410/21 = 200
C0410/22 = 200
C0410/23 = 200
C0410/24 = 200
C0412/1 = 200
C0412/2 = 200
C0412/3 = 200
C0412/4 = 200
C0412/5 = 200
C0412/6 = 200
C0412/7 = 200
C0412/8 = 200
C0412/9 = 200
C0410/x = 30 45
C0415/x = 60 75
C0417/x = 60 75
C0418/x = 60 75
C0417/x = 80 95
C0418/x = 80 95
C0421/x = 52
C0421/x = 53
C0412/x = 20
C0419/x = 50
C0421/x = 50
FIF-IN.W2.B0 FIF-IN.W2.B15
FIF-IN.W3
FIF-IN.W4
FIF-IN.W2
C0410/x = 50 65
C0412/x = 22
C0412/x = 23
C0415/x = 80 95
C0419/x = 52
C0419/x = 53
C0412/x = 21
C0419/x = 51
C0421/x = 51
Byte 27, 28
Byte 25, 26
FIF-IN.W1.B0 FIF-IN.W1.B15
Byte 34
Byte 36
Byte 33
Byte 35
CTRL.B0
CTRL.B0
CTRL.B1
CTRL.B1
CTRL.B2
CTRL.B2
CTRL.B13
CTRL.B13
CTRL.B14
CTRL.B14
CTRL.B15
CTRL.B15
DRIVECOM-CTRL PROFIdrive-CTRL
FIF-OUT
FIF-IN
C1511/4 = 5
C1511/3 = 4
C1511/2 = 3
C1511/1 = 17
C1511/5 = 6
C1511/6 = 7
C1511/7 = 8
C1511/8 = 9
C1511/9 = 10
C1511/10 = 11
PROFIBUS
POW4 POW4
POW3 POW3
POW2 POW2
POW1 POW1
POW5 POW5
POW6 POW6
POW7 POW7
POW8 POW8
POW9 POW9
POW10 POW10
A
B
CN
FIF-RESERVED
FIF-RESERVED
FIF-RESERVED
FIF-RESERVED
FIF-RESERVED
FIF-RESERVED
FIF-RESERVED
FIF-RESERVED
FIF-RESERVED
8200vec512
Fig. 7−1 Free configuration of the 10 PROFIBUS process output words