Communication−relevant Lenze codes
10
l
91
EDS82ZAFPC201 EN 4.0
10.2 Communication−relevant Lenze codes
C1509: Bus device addressing
Code Subcode Index
Possible settings
Data type
Lenze Selection
C1509 23066
d
=
5A1A
h
3 3 [1] 126 FIX32
This code serves to set the bus device address. The setting in this code is only effective if the
DIP switches S1 ... S7 are set to OFF.
) Note!
ƒ The bus device addresses of networked controllers must differ from each
other.
ƒ Switch off the voltage supply of the function module and the controller, and
then switch it on again to activate the changed settings.