Technical data
General data
4
l
14
EDS82ZAFPC201 EN 4.0
4 Technical data
4.1 General data
Area Values
Order designation E82ZAFPC201
PUO ID number 0x081B
hex
Communication profile
(DIN 19245 Part 1 and Part3)
l PROFIBUS−DP−V0
l PROFIBUS−DP−V1
Communication medium RS485
Drive profile l DRIVECOM profile "Drive technology 20" (can be switched off)
l PROFIdrive (can be switched off, state machine and PROFIdrive parameter
data channel)
Network topology l Without repeaters: line
l With repeaters: line or tree
PROFIBUS bus device Slave
Baud rate [kbps] 9.6 ... 12000 (automatic detection)
Process data words 1 ... 10 words
(16 bits/word)
DP user data length 1 ... 10 process data words +
4 parameter data words
Max. number of bus devices l Standard: 32 (= 1 bus segment)
l With repeaters: 125
Max. cable length per bus
segment
1200 m (depending on the baud rate and cable type used)
External DC voltage supply +24 V DC ±10 %, max. 100 mA
4.2 Operating conditions
Ambient conditions
Climate
Storage
IEC/EN 60721−3−1 1K3 (−25 to +60 °C)
Transport IEC/EN 60721−3−2 2K3 (−25 to +70 °C)
Operation Corresponding to the data of the Lenze standard device used (see documentation
of the standard device).
Pollution EN 61800−5−1 Degree of pollution 2
Degree of protection IP20 (protection against accidental contact according to NEMA 250 type 1)