11 Implemented PROFIdrive objects
) Note!
The following indices can only be accessed via DPV1.
I−918
hex
: Display of bus device address
Index
918hex
Name
Subindex Default setting Values Access Data type
−
g
1 [1] 126 R U16
This PROFIdrive index displays the set bus device address.
I−963
hex
: Baud rate
Index
963hex
Name
Subindex Default setting Values Access Data type
−
g
0: 9.6 kbps
R
U16
1: 19.2 kbps
2: 93.75 kbps
3: 187.5 kbps
4: 500 kbps
6: 1.5 Mbps
7: 3 Mbps
8: 6 Mbps
9: 12 Mbps
10: 31.25 kbps
11: 45.45 kbps
This PROFIdrive index displays the baud rate of the PROFIBUS.
I−964
hex
: Device identification
Index
964hex
Name
Subindex Default setting Values Access Data type
0:
g
262: Manufacturer: Lenze
R
U16
1:
g
8201: Device type
2:
g
xxyy: Software version,
e.g. 0090 (V 0.90)
3:
g
yyyy: Firmware date: year,
e.g. 2005
4:
g
ddmm: Firmware date: day/month,
e.g. 0506 (5 June)
This PROFIdrive index displays the device identification.