EasyManua.ls Logo

Lenze E82ZAFPC201 - PROFIdrive DP-V0

Lenze E82ZAFPC201
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter data transfer
PROFIdrive parameter data channel
PROFIdrive DP−V0
8
l
64
EDS82ZAFPC201 EN 4.0
8.2.1 PROFIdrive DP−V0
) Note!
The communication module described in this manual corresponds to the
PROFIdrive profile version 3.0. The PROFIdrive parameter data channel (DP−V0)
has already been defined in the PROFIdrive profileversion 2.0 and is kept
merely for compatibility reasons.
We recommend the use of the PROFIdrive parameter data channel (DP−V1) for
new configurations.
8.2.1.1 Telegram structure
The PROFIdrive parameter data channel is located (same as the DRIVECOM parameter data
channel) in the first 8 bytes of the cyclic data.
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8
Parameter identification
(PKE)
Subcode
(IND)
Reserved Parameter value (PWE)

Table of Contents