Parameter data transfer
PROFIdrive parameter data channel
PROFIdrive DP−V0
8
l
65
EDS82ZAFPC201 EN 4.0
Byte 1 / 2: Parameter identification
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8
Parameter identification
(PKE)
Subcode
(IND)
Reserved Parameter value (PWE)
ƒ Parameter identification structure
Byte 1 Byte 2
4 3 2 1 12 11 10 9 8 7 6 5 4 3 2 1
Request/response
identification
Code
ƒ Request/response identification (high nibble of byte 1)
PKE Request identification
0 No request
1 Read single parameter
2 Write single parameter (word)
3 Write single parameter (double word)
6 Read array parameter
7 Write array parameter (word)
8 Write array parameter (double word)
PKE
Response identification
Positive Negative
0 No response
1 Transmit single parameter value (word)
2 Transmit single parameter value (double word)
4 Transmit array parameter value (word)
5 Transmit array parameter value (double word)
4 Transmit array parameter value (word)
5 Transmit array parameter value (double word)
7 Request cannot be executed,
see error number
ƒ Code (low nibble of byte 1 and byte 2)
ƒ Value range: 0 ... 2000 (C0001 ... C1999)
Byte 3: Lenze subcode
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8
Parameter identification
(PKE)
Subcode
(IND)
Reserved Parameter value (PWE)
ƒ Value range: 0 ... 255
Byte 4: Reserved (0)
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8
Parameter identification
(PKE)
Subcode
(IND)
Reserved Parameter value (PWE)