EasyManua.ls Logo

Lenze E94AYCEO - Page 112

Lenze E94AYCEO
149 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lenze · E94AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 12/2013 · TD17 112
13 Parameter reference
13.3 Parameters of the communication module for slot MXI2
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14863
C14870
Parameter | Name:
C14863 | Ethernet Port
Data type: UNSIGNED_16
Index: 9712 = 0x25F0
Display of the baud rate currently used on the Ethernet connections
Selection list (read only)
0 Nonexistent
1 10 Mbps/Half Duplex
2 10 Mbps/Full Duplex
3 100 Mbps/Half Duplex
4 100 Mbps/Full Duplex
5 Reserved
6 Reserved
Subcodes Info
C14863/1 Ethernet port X233 link state
C14863/2 Ethernet port X234 link state
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14870 | CIP Connections State
Data type: UNSIGNED_16
Index: 9705 = 0x25E9
Display of the current CIP connection status
Selection list (read only)
0 Nonexistent
3 Established
4 Timed Out
Subcodes Info
C14870/1 Status of CIP connection 1
... ...
C14870/8 Status of CIP connection 8
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT

Table of Contents

Related product manuals