C13002
C13003
C13010
C13011
Parameter | Name:
C13002 | Gateway address
Data type: UNSIGNED_32
Index: 11573 = 0x2D35
Setting of the gateway address
Setting the IP configuration
( 37)
Setting range (min. value | unit | max. value) Lenze setting
0 4294967295 0
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13003 | MAC ID
Data type: OCTET_STRING
Index: 11572 = 0x2D34
Display of the MAC-ID
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13010 | Active IP address
Data type: UNSIGNED_8
Index: 11565 = 0x2D2D
Display of the active IP address
The active IP address may differ from the contents of code C13000
, depending on whether the station name was
changed via the fieldbus or the parameter(C13899
).
Display range (min. value | unit | max. value)
0 255
Subcodes Info
C13010/1 Active IP address.1
C13010/2 Active IP address.2
C13010/3 Active IP address.3
C13010/4 Active IP address.4
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13011 | Active subnetwork mask
Data type: UNSIGNED_8
Index: 11564 = 0x2D2C
Display of the active subnetwork mask
The active subnet mask may differ from the contents of code C13001
, depending on whether the station name was
changed via the fieldbus or the parameter (C13899
).
Display range (min. value | unit | max. value)
0 255
Subcodes Info
C13011/1 Active subnetwork mask.1
C13011/2 Active subnetwork mask.2
C13011/3 Active subnetwork mask.3
C13011/4 Active subnetwork mask.4
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT