Lenze · E94AYCER communication module (PROFINET®) · Communication Manual · DMS 11.0 EN · 04/2016 · TD17 95
14 Parameter reference
14.2 Parameters of the communication module for slot MXI1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13012
C13850
C13851
Parameter | Name:
C13012 | Active gateway address
Data type: UNSIGNED_8
Index: 11563 = 0x2D2B
Display of the active gateway address
The active gateway address may differ from the contents of code C13002
, depending on whether the station name
was changed via the fieldbus or the parameter (C13899
).
Display range (min. value | unit | max. value)
0 255
Subcodes Info
C13012/1 Active gateway address.1
C13012/2 Active gateway address.2
C13012/3 Active gateway address.3
C13012/4 Active gateway address.4
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13850 | All words to master
Data type: UNSIGNED_16
Index: 10725 = 0x29E5
Display of the process data words which are transmitted from the communication module to the I/O controller.
In the subcodes 1 to 32, all process data words to the I/O controller are displayed. However, only the configured
process data words are valid.
Display range (min. value | unit | max. value)
0 65535
Subcodes Info
C13850/1
...
C13850/32
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13851 | All words from master
Data type: UNSIGNED_16
Index: 10724 = 0x29E4
Display of the process data words which are transmitted from the I/O controller to the communication module.
In the subcodes 1 to 32, all process data words from the I/O controller are displayed. However, only the configured
process data words are valid.
Display range (min. value | unit | max. value)
0 65535
Subcodes Info
C13851/1
...
C13851/32
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT