CMVETH01B 46
Cyclic Data Access
5.7.6.9 P45x = 9, Analog 0-10V Input
Analog Input: 0 - 10V in 0.1 VDC increments
Received Value = 0x3A = 5.8 VDC
5.7.6.10 P45x = 10, Analog 4-20mA Input
Analog Input: 4 - 20mA in 0.1 mA increments
Received Value = 0xA5 = 16.5 mA
5.7.6.11 P45x = 11, Actual PID Setpoint
Signed value: -999 to 31000
5.7.6.12 P45x = 12, Actual PID Feedback
Signed value: -999 to 31000