Device parameters and interfaces
Leuze electronic BPS 34 71
TNT 35/7-24V
8.1.7.14 Module 13: Min./max. position
Note!
Underlined in the CR column are the modules which must be activated in addition to the cur-
rent module.
Description
The min/max position function monitors the position value and transfers the maximum/
minimum value to the PROFIBUS master.
The acquisition time can be adjusted by means of two different modes:
• The "all values" mode detects all values since the start of measurement or since a
reset event.
• The "in measurement value window only" mode only detects extreme values which
occur in the time period defined in the "MinMax period" parameter.
Parameters
Hex coding of module 13 "Min./max. position"
The value listed in the table shows the hex coding of the default settings.
Parameter Description Rel.
addr.
Data
type
Value range Default Unit CR to
module
MinMax
mode
Parameter activates the min/max
evaluation function.
0
unsign
8
0: Off
1: All values
2: In measurement value
window only
0 ––
MinMax
period
Defines the measurement value
window for the min-max values.
1
unsign
8
0 … 255 10
Mea-
sure-
ments
–
Parameter length: 2 byte
Internal address
of module 13
MinMax mode
address 0
MinMax period
address 1
0C 00 0A