General
8 SOLID-2 Leuze electronic
Review-Stand, , 8. April 2015
DEUTSCH ENGLISH FRANÇAIS ITALIANO ESPAÑOL NEDERLANDS
1.3 Selecting a SOLID-2
1.3.1 SOLID-2 Safety Light Curtains
Fig. 1.3-1: Selecting a SOLID-2 Safety Light Curtain
SD2trr-xxxx v*
SOLID-2
t - Type of device
T: Transmitter
R: Receiver
r - Resolution
20: 20 mm
30: 30 mm
40: 40 mm
90: 90 mm
xxxx- Protective field height
150 ..... 1800 mm (for 20, 30 and 40 mm resolution)
600..... 3000 mm (for 90 mm resolution)
v- Function version
E: Extended version (with selectable start/restart
interlock and contactor monitoring)
Standard version (automatic start/restart without
contactor monitoring)
*) In the Standard version this place in the product
designation is not used