WAB-3003 108M 11g Outdoor PoE CPE/ AP/ Bridge
86
Trap: Whe
n enabled, events on Cold Start, Interface UP & Down, and Association &
Disassociation can be reported to an assigned server.
o Enable/ Disable: Select Enable to activate this function or Disable to inactivate it.
o Server IP Address: Enter the IP address of the assigned server for receiving the trap
report.
System Log: By enabling this function, specify a remote Syslog server to accept system log
messages from the system remotely.
Enable/ Disable: Select Enable to activate this function or Disable to inactivate it.
SYSLOG Server IP: The IP address of the Syslog server for receiving the reported events.
Server Port: The port number of the Syslog server.
SYSLOG Level: Select the desired level of received events from the drop-down list box.
UPnP Configuration: This option can be enabled if UPnP service is required by LAN device.
Enable/ Disable: Select Enable to activate this function or Disable to inactivate it.
Auto Reboot: The system can be functioning in a healthier state when this service is enabled.
Enable/ Disable: Select Enable to activate this function or Disable to inactivate it.
Reboot Time: Select an appropriate time from the drop-down list box. Since all users on the
network will be disconnected during reboot, it is suggested to set the reboot time during an
off-peak period to reduce impacts on the online users.