Lexmark MS415 - Base Sensor Test; Device Tests; Flash Test

Lexmark MS415
303 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Base Sensor Test
Use this to determine that the sensors located inside the printer are operating correctly.
The following sensors can be checked using this test:
Narrow Media
Input
Exit/Output
Front Door
CAUTION—SHOCK HAZARD: Do not use your hand to toggle these switches. Use a nonconducting item.
To run the test:
1 From the Diagnostics menu, navigate to Base Sensor Test.
2 Choose a sensor.
3 Manually actuate the sensor to verify that it toggles. If the sensor does not toggle, then it is malfunctioning.
Sensor Values
Input
Exit/Output
Front Door
Open
Closed
Narrow Media Narrow
Wide
4 Press X to exit the test.
Device Tests
Flash Test
This test verifies the condition of the flash device by writing data to it and then reading data from it.
Warning—Potential Damage: This test destroys all data on the flash device.
Note: After this test is executed, reformat the flash using the Flash Format setting in the Utilities menu.
1 From the Diagnostics menu, navigate to:
Device Tests > Flash Test
Contents will be lost. continue? appears.
2 Select Yes to continue the test, or select No to return to the Device tests menu.
3 After the test is complete, the result appears.
4 Reformat the flash device using the Flash format setting in the Utilities menu.