Actions Yes No
Step 4
Check the following fuser components for wear or damage:
• Gears
• Exit rollers
• Belt fuser
Are they free of damage?
Go to step 5. Replace the fuser. See
“Fuser removal” on
page 238.
Step 5
a Turn off the printer.
b Remove the rear door and cover.
c Disconnect the fuser cable connected to PCN5 of the power supply.
d Check for approximate correct resistance on the fuser cable:
• 220 V fuser—43 ohms
• 110 V fuser—10 ohms
• 100 V fuser—8 ohms
Is the resistance equal to any of the above values?
The problem is solved. Replace the fuser. See
“Fuser removal” on
page 238.
Skewed print check
ABCDE
ABCDE
ABCDE
Actions Yes No
Step 1
a POR into the Diagnostics menu and perform a print test:
Diagnostics Menu > Print Tests > Tray 1
b Adjust the margins if necessary:
Diagnostics Menu > Registration
Does the error remain?
Go to step 2. The problem is solved.
Step 2
Does the skew appear every two pages?
Go to step 9. Go to step 3.
Step 3
Check the media source.
Is the media from Tray 1?
Go to step 4. If the media is from the
MPF, then go to step 6.
4514
Diagnostic information
36