Sensor (staple finisher pass‑through) removal
1 Remove the staple
finisher
left cover. See “Staple
finisher
left cover removal” on page 584.
2 Remove the staple finisher right cover. See “Staple finisher right cover removal” on page 586.
3 Remove the staple
finisher
diverter plunger assembly. See “Staple
finisher
diverter plunger assembly
removal” on page 604.
4 Remove the staple
finisher
drive gear assembly. See “Staple
finisher
drive gear assembly removal” on
page 604.
5 Remove the staple finisher feed roll. See “Staple finisher entrance roller removal” on page 632.
6 Remove the staple finisher chute assembly. See “Staple finisher chute assembly removal” on page 634.
7 Disconnect the cable (A), remove the screw (B), and then remove the sensor bracket.
AB
8 Remove the sensor from the bracket.
4064
Parts removal
643