Function
Product
Description Option
Air
Conditioner
Ventilation
Low Noise
Mode Time
○ ○
A function to set the start time
and end time of the outdoor unit
low noise mode operation.
• The outdoor unit low noise operation time settings
function can be set only when the installer settings’
outdoor unit function M / S setting is ‘Master’, and
the outdoor unit low noise control reference setting
is ‘Remote controller.’
Advanced
Fan Speed
“Auto”
○
A function to set the auto fan
usage based on the temperature
of the indoor unit.
ON / OFF
Human
Detection
Mode
○
It is the function to set the
operation of human detection
mode.
Saving Operation
Time
• OFF: Not using the Human detection
power-saving operation.
• On / Off Control : When no user is
detected for a set time, the product is
turned OFF for saving power.
• Temp. Control : When no user is
detected for a set time, the desired
temperature of the product is
controlled for saving power.
• Energy-saving operation based
on activity : It can control the set
temperature in accordance with the
activity and save energy.
5 / 10 / 15
/ 30 / 60 /
90 min.
Top And
Bottom
Selection
○
This is a function to set the usage
of the upper and lower vanes
when operating the product.
Concurrency (whole) / Top / Bottom
My Favorite
Temperature
○
A function to set the desired
temperature in initial operating
mode when the user saves a set
desired temperature.
ON / OFF
Economizer
○
A function to supply external air
into the room for saving energy
and improving room air quality.
• OFF: Cancel the economizer function and keep the
damper closed.
• Auto: When the external air condition is lower than
the room air condition in case of cooling operation,
the external air is supplied to the room to save
energy.
• Step1: Opens the outer air damper opening by
one stage to improve the indoor air quality by
introducing fresh air into the room.
• Step2: Opens the outer air damper opening by
two stages to improve the indoor air quality by
introducing fresh air into the room.