41
Function
Product
Description Option
Air
Conditioner
Ventilation
Over Cooling
○ ○
Control the cooling thermal ON / OFF
temperature conditions.
※ Caution: If you incorrectly set it, it
may cause overheating or weak
heating.
Thermal On Thermal Off
Step 0
Operates in accordance with
the product set value
Step 1
6 °C
(12 °F)
4 °C (8 °F)
Step 2 4 °C (8 °F) 2 °C (4 °F)
Step 3 1 °C (2 °F)
-1 °C
(-2 °F)
Static Pressure
Step
○
This function allows you to set the
static pressure of the duct product by
subdividing it into 11 steps.
Stage 0-Stage 11
• If the static pressure stage settings are
used, the static pressure settings are not
used.
• Please refer to the indoor unit product
manual for the static pressure value for
each stage.
Guard Timer
○
Set the outdoor unit cycle conversion
operation standby time, and set the
outdoor unit protection time for cycle
conversion.
Stage 0: 0 min. / Stage 1: 15 min. /
Stage 2: 30 min. / Stage 3: 45 min. /
Stage 4: 60 min.
Fan Speed
In Cooling
Thermal Off
○ ○
A function to set the operation of the
indoor unit fan during the cooling
thermal OFF operation.
Low / Off / Setting
Primary Heater
○
A function to set the control to be
conducted with priority on the heater
usage than the outdoor unit cycle in
case of operation of the indoor unit
heating.
ON / OFF
AC. Fan Oper.
Interlocked
With Vent.
○
When the air conditioner and the
ventilation product are interlocked for
operation, the function sets whether to
operate the fan of the air conditioner.
ON / OFF
IDU Auto-Start
○ ○
In the event of a power outage, you
can set whether to recover the product
to its previous operating state.
Enabled: Reset to the previous operation
status.
Disabled: Reset to the operation OFF
status.
Occupancy
Duration Time
○
A function to set the absence
determination maintenance time
among the in-room sensor values.
0 / 10 / 30 / 60 min.