43
Function
Product
Description Option
Air
Conditioner
Ventilation
Fan Continuous
Operation
○
A function to set the fan non-stop
function usage of indoor unit. (A
function to operate the fan of the
indoor unit for longer than the
conventional operation method in the
outdoor unit for maximizing the cooling
/ heating efciency.)
ON / OFF
Low Noise
Mode Priority
○ ○
A function to set the control subject of
the low noise mode. (A function to set
only one of the outdoor unit and the
remote controller to be able to manage
the low noise operation.)
Outdoor unit / Remote controller
Lamp Color
Setting
○
This function selects the LED color
to display the ne dust status of the
product.
Auto / RGB / YGG
Dust Step Color
Setting
○ ○
You can change the color display
method for each stage of ne dust
according to national standards.
• Type 1: Stage 4 (Republic of Korea)
• Type 2: Stage 4 (Global)
• Type 3: Stage 6 (China)
Human
Detection
Sensor
○
It is the function to set whether to
install human detection sensor and
operation standard value.
Value Description
Human
Detection
Sensor
Not installed, Forward,
Rotate 90°
Sensing
Period
• Type 1: 5 sec, 30 sec, 1
min, 3 min
• Type 2: 5 sec, 10 sec, 30
sec, 1 min
※ For Type 2, apply it only
when the indoor unit
product has the custom
temperature settings
function.
Sensitivity Low, High
Temperature
Control Option
• Step0: Maintain the
product operation and use
the temperature power-
saving function.
• Step1: Use the
temperature power-saving
function and stop the
operation of the indoor
unit.
Detection Area
Large, Small, Indoor Floor
Area Detection