44
Function
Product
Description Option
Air
Conditioner
Ventilation
Humidity
Sensing
Position
○
A function to decide where to detect
humidity.
Remote controller / Indoor unit
ODU Cycle
Priority
○
You can select standby or cooling.
• Disabled: It does not support the opposite
cycle operation with the wired remote
controller.
• Cooling: When the user has selected the
opposite operation mode by the wired
remote controller, the indoor unit stops the
heat exchange and the fan.
• Standby: There is a priority on the cooling
cycle. When the user has changed the
operation mode of a specific indoor unit
into the cooling or heating cycle, the
outdoor unit is switched into the cooling
cycle and the indoor unit maintains the
heating operation by using the heater.
※ Before using this function, please set
the emergency heater or external heater
function.
Outdoor Temp.
For Heating
Stages
○
You can set the outdoor temperature
based on the temperature of the
heater combination heating mode.
-
Estimated
Energy Display
○
A function to set the display of the
energy data measured by the outdoor
unit.
ON / OFF
CN_PTC
○
This is a function to set PTC Port of
indoor unit.
ON / OFF
Temperature
Compensation
○
You can display on the screen by
applying the compensation value to
the temperature value detected by the
remote controller.
In case of Celsius: -5 °C to +5 °C (by the
unit of 0.5 °C)
In case of Fahrenheit: -10 °F to 10 °F (by
the unit of 1 °F)
Humidity
Compensation
○
Compensation value can be applied
to the humidity value detected by the
remote controller to display on the
screen.
-10% to +10% (by the unit of 1%)
Dust Lamp
Always
Displayed
○
A function to set whether to regularly
display the dust concentration on the
LED lamp mounted on the indoor unit
product.
ON / OFF