LGMG North America Inc.
Operation and Safety Manual
36
47
“The platform handle is not in the middle position” error during start
The speed is reduced to the speed
after lifting
52
Forward coil error
Stop lifting and running
53
Backward coil error
Stop lifting and running
54
Lifting error of lifting coil
Stop lifting and running
55
Lifting error of lowering coil
Stop lifting and running
56
Right turn coil error
Stop lifting and running
57
Left turn coil error
Stop lifting and running
58
Brake coil error (because the brake coil is optional, this function is
temporarily shielded)
Stop lifting and running
60
Motor controller error
Stop lifting and runningTriplat only
61
Electric drive motor controller current sensor error (overheating of
running or lifting motor)
Display alarm only
62
Motor controller hardware damage error
Display alarm only
63
Motor controller motor output error
Display alarm only
64
Motor controller SRO error
Display alarm only
65
Motor controller throttle valve error
Display alarm only
66
Motor controller emergency reverse error
Display alarm only
67
Motor controller HPD error
Display alarm only
68
Low voltage alarm
Stop all actions
69
High neutral current (MC is detecting current in the motor, but there
shall be no current in this case)
Stop lifting and running
70
The steering input is beyond the range (the improper voltage is in the
steering input)
Stop lifting and running
71
Motor controller main contactor error
Stop lifting and running
72
Motor controller overvoltage error
Display alarm only
73
Motor controller heat reduction error
Display alarm only
74
Motor controller motor error
Display alarm only
75
Motor controller pump motor error
Display alarm only
76
Motor controller left drive motor error
Stop lifting and running
77
Motor controller right drive motor error
Triplat prohibits lifting and walking
combiacx shows only alarms
78
Pump motor short circuit error
Triplat show only alarms combiacx
prohibits lifting and walking
79
Left drive motor short circuit error
Stop lifting and running
80
Alarm of exceeding 80% load
Alarm only
81
Right drive motor short circuit error
Stop lifting and running
82
Left brake coil error
Stop lifting and running
83
Right brake coil error
Stop lifting and running