1. Dry t the mounting plate (Fig.20C) and the leveling
sensor (Fig.20B) to the crossmember (Fig.20A). The pre-
drilled holes closest to the rounded edges are for mounting
the sensor to the plate. Mark on the plate where the sensor
will set.
Fig.20
NOTE: Make sure there is a space between the sensor
and crossmember so the wire harness is not pinched.
NOTE: The wire harness MUST be pointed toward the
front of the trailer. Orientation is imperative for the correct
operation of the leveling system.
2. Attach the sensor (Fig.21A) to the mounting plate
(Fig.21B) using two #12 x 1” screws (Fig.21C).
Fig.21
NOTE: To avoid cracking the mounting sensor housing,
do not over-tighten the screws.
3. Attach the mounting plate and sensor assembly
(Fig.22B) to the crossmember (Fig.22A) using two #12 x 1”
screws (Fig.22C). Make sure that the plate is centered side
to side on the frame and that the sensor is oriented properly.
See gure 18, sections A and B, for location clarication.
Fig.22
4. Connect the sensor harness to the 3-pin Deutsch
Connector on the sensor (Fig.23A) and run the harness
through the frame and up to the compartment where the
controller will be mounted.
Fig.23