Lite-On Technology Corp.
Industrial Automation
104
Internal torque limit1/Internal Torque Command
1
Communication
address:
0006H
0007H
Internal Torque Command 1: The setting of the internal torque command in the first segment (TCM0,TCM1) =
(1,0).
Internal Torque Limit 1: The setting of the internal torque limit in the first segment (TCM0,TCM1) = (1,0).
Internal torque limit 2/internal torque command
2
Communication
address:
0008H
0009H
Internal Torque Command 2: The setting of the internal torque command in the second segment (TCM0,TCM1)
= (0,1).
Internal torque limit 2: The second configuration for the internal torque limit (TCM0,TCM1) = (0,1).