PB-XX (Gain/filtering parameter)
PB-00
SFIL
The acceleration-deceleration smoothing
constant of the analog speed command
Communication
address:
0100H
0101H
Initial value
0
Control mode
S
Unit
ms
Configuration range
0 ~ 1000 (0: The function is turned
off.)
Data size
16bit
Data format
Dec
PB-01
TFIL
Smoothing constant of the analog torque
command
Communication
address:
0102H
0103H
Initial value
0
Control mode
T
Unit
ms
Configuration range
0 ~ 1000 (0: The function is turned
off.)
Data size
16bit
Data format
Dec
Speed command
Torque command

Table of Contents