cable and the torch lead on one side of your body. Keep your body from coming in between the torch
lead and the work cable. (2) Keep distance of work cable to workpiece as short as possible to
eliminate loop areas. (3) Route torch leads as close as possible to work cable. (4) Do not wrap the
torch lead or work cable around your body. (5) Stay as far away from power source as possible.
SAFETY DEVICES - The Plasma Units used on Vulcan have safety interlocks to prevent danger to
personnel and damage to machine.
Do not try to short out or override these interlocks! Check
interlocks and all safety related parts of Plasma Unit frequently and replace them
IMMEDIATELY if
they are not working!
The interlocks turn off the power supply when the retaining cap is loosened.
Never bypass or shortcut the safety interlocks on any of the plasma system units.
Do not use the Plasma Unit unless all of its power supply covers are in place; failure to do so will
ENDANGER the operator and other persons near the machine and it will interfere with cooling of vital
parts of Unit, which can be damaged as a result.
Be certain that all electrical connections are covered with appropriate insulation material. Cracked
insulation must be replaced!
Each plasma unit is designed to be used only with specific Vulcan torches. Do not substitute other
torches which could overheat and present a potentially dangerous situation to the operator and any
personnel in the area.