9. Reconnect the optical fibers to the Bit-Driver.
10. Repeat tests 1 to 9, as necessary, for the remote Bit-Driver.
11. If a defect is still not isolated, the F/O cable may be defective. Its continuity can be roughly
checked by placing connector at one end near a 60 watt or larger light. (
CAUTION: excessive heat
may damage connector) At the other end light should be visible coming from the fiber. If not, the fiber
is defective.
IMPORTANT! IF, AFTER PERFORMING TROUBLESHOOTING YOU FIND UNITS STILL NOT
WORKING, CHECK WITH A S.I. TECH SALES APPLICATION ENGINEER FOR OPTICAL UNIT
SERVICE CALL OR WRITE S.I. TECH, P.O. BOX 609, GENEVA, IL., 60134,; PHONE (630) 232-
8640.
WARNING: This equipment generates, uses, and can radiate radio frequency energy, and if not
installed and used in accordance with the instructions manual, may cause interference to radio
communications. It has been tested and found to comply with the limits for a Class A computing
device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable
protection against such interference when operated in a commercial environment. Operation of this
equipment in a residential area is likely to cause interference, in which case the user, at his own
expense, will be required to take whatever measures may be required to correct the interference.