Top climate system
with LUBING Touch Controller
Copyright © Lubing System - All rights reserved
35
If the “auto VPD” running mode is selected, the spraying ratio is proportional to the position of the calculated VPD
in the control range:
5.7.6 Special functions
Use the Options key to select the “Special functions” main menu.
The following parameters can be set here:
PARAMETER DESCRIPTION
Box wetting
The system sprays without interruption until the set wetting time
has elapsed. If the “Wetting” function is activated, “House wetting”
appears in the status display. After wetting, the system switches
off automatically.
Note: The wetting process can be stopped prematurely with the
ON/OFF button.
System flushing
This function enables the pressure lines to be cleaned.
Prerequisite: The ball valves at the end of the lines must rst be
opened. When the ushing function is activated, the pressure
switch query is automatically ignored so that the system can be
ushed without pressure.
Note: The ushing process is terminated again by pressing the OK
key.
In the LCM controller versions, the sections to be ushed must be
selected in blocks. Each connected IO card is selected separately.