5.7.7 System parameter
Use the options key to select the “System parameter” main menu.
The following parameters can be set here:
PARAMETER DESCRIPTION
Language
You can choose a language from the list of supported languages.
Adjust time
You can set the time.
The time is only required for the “Daily timer” function.
Note: if the controller is not supplied with power for a longer period
of time (approx. 3 days), the time must be adjusted again when it is
put back into operation.
Release time
The release time of the electric pressure release of the pump is set.
The factory setting of 3 sec. is sufcient in most cases. Only with
very long lines the value can be increased if necessary.
Pressure switch
The pressure switch monitoring can be switched off and on again.
When the system has reached the operating pressure, the color in
the circle next to the time changes from white to blue.
Note: If the system does not reach the operating pressure, the
pressure switch can be switched off to enable troubleshooting.
If only the pressure switch is defective, this can also enable
emergency operation until spare parts are available.
ATTENTION: if the pressure switch query is switched off,
there is no longer any protection against dry running of the
pump and against water damage in the stable!
Press. wait time
The wait time until the pressure switch is checked can be set.
Setting recommendation: approx. 10 sec., so that the pump is not
stopped when starting. For very long lines, it may be necessary to
adjust the value upwards.
ATTENTION: the pressure switch waiting time should be
shorter than the set spraying time. This is the only way to
protect against dry running or water damage.
Note: if the system takes much longer than 10 seconds to build up
pressure, this probably indicates a fault in the system.
Min spraying time
The minimum spraying time can be set to a minimum of 5 sec-
onds. This ensures that the system is not switched off again during
pressure build-up. If pressure build-up takes longer (big systems),
then the value should be increased. In addition, the spraying time
cannot be set shorter than the pressure waiting time.
Min breaking time
The minimum breaking time can be set to a minimum of 5 sec-
onds. Under extreme conditions, the system switches to con-
tinuous operation (without breaking time; spraying ratio 100%).
Interval auto mode
The interval operation for automatic mode can be switched on
or off. Applies only to the “auto extern” operating mode (enables
interval control to be implemented in the climate computer).
Operating hours
Shows the cumulated on-time of the pump
Next oil change in
Display of the remaining operating hours until the next oil change.
When the time has expired, an information message appears on
the display. This info message can be conrmed with OK - this
automatically resets the oil change interval.
The factory setting is 50h (new pump unit). After the rst oil change
the value is reset to 500h.
Reset oil hours
After an oil change, the oil change interval can be manually reset
here. This should be done, for example, if an oil change was made
before the rst use of the year in systems that are not used during
the winter months.
lubingsystem.com
lubingsystem.com
lubingsystem.com
lubingsystem.com
lubingsystem.com
lubingsystem.com
lubingsystem.com
lubingsystem.com
lubingsystem.com
lubingsystem.com
lubingsystem.com
lubingsystem.com
lubingsystem.com
lubingsystem.com
lubingsystem.com
lubingsystem.com
lubingsystem.com
lubingsystem.com
lubingsystem.com
lubingsystem.com
c
lubingsystem.com
lubingsystem.com