Read this operating instructions before start up!
To be retained for future reference.
Operating Instructions
MODULAR
FLOW METER SYSTEM TS
with and without volume preselection

Table of Contents

Questions and Answers

  • K
    Kenneth WagnerJul 28, 2025
    Why does 'Batt' indication flash on my Lutz ST?
    • M
      Mary GalvanJul 28, 2025
      The 'Batt' indication might flash or remain permanently on because the battery service life has ended, the batteries are fitted incorrectly, or the battery contacts are corroded. To resolve this, replace the batteries, check the polarity of the batteries, or clean the battery contacts.
  • A
    Alice PearsonAug 2, 2025
    What to do if liquid leaks from the housing of Lutz Measuring Instruments?
    • W
      williamsjosephAug 2, 2025
      If liquid leaks from the housing, it could be due to a defective seal, hairline cracks in the housing or screw connection, or a screw connection that isn't tightened securely. You should replace the seal, check the installation conditions for mechanical stresses and correct them, and ensure that screw connections are secure.
  • T
    Trevor BairdAug 7, 2025
    What to do if Lutz ST filling process is interrupted?
    • J
      Joshua PooleAug 7, 2025
      If the filling process is interrupted and 'STOP' appears on the display, it could be that the solenoid valve does not open or the time required to fill the connecting lines exceeds the set monitoring time. Check the solenoid valve. Also, consider increasing the monitoring time.
  • C
    Courtney HernandezAug 11, 2025
    Why is the throughput decreasing in my Lutz ST Measuring Instruments?
    • L
      Lisa BeckerAug 12, 2025
      A decrease in throughput may be due to inadequate chemical resistance, a soiled filter screen, or a soiled measuring chamber. Contact the manufacturer, remove and clean the filter screen, or regularly flush and clean the flow meter, especially after handling aggressive, tacky, crystallizing, or very contaminating liquids.
  • J
    Jay HernandezAug 17, 2025
    Why Lutz ST Measuring Instruments shows different quantity from the actual quantity?
    • R
      Robert VaughanAug 17, 2025
      If the measured quantity differs significantly from the actual quantity, it could be because the correction factor does not match operating conditions or the wrong unit of measure is set. Calibrate the flow meter or set the correct unit of measure.
  • J
    jonathon65Aug 21, 2025
    How to fix no liquid registered by Lutz ST Measuring Instruments?
    • M
      Ms. Vanessa ButlerAug 22, 2025
      If no liquid is registered, it may be due to a correction factor of 0 in the main memory, leaks in the hose system, or dry running. Calibrate the flow meter, install a check valve if necessary, and prevent air pockets in connecting lines by using a solid hose system.

Summary

Flow Meter Operating Instructions

General System Overview

System Hazard Information

Explains potential dangers and user responsibilities for the flow meter system.

Safety Symbol Reference

Details safety symbols used in the manual and their meanings.

Basic Flow Meter Technicals

Basic Flow Meter Usage and Safety

Covers general usage guidelines and specific safety for explosion hazard areas.

Flow Meter Installation Guide

Drum Pump Connection Setup

Step-by-step instructions for connecting the flow meter for drum pump operation.

Flange Connection for Piping

Guidance on connecting the flow meter to piping systems using flange connections.

Operating Unit Functions and Control

Operating Unit Functions and Data

Covers proper use, technical data, and electrical specifications for the operating unit.

Explosion Hazard Area Operation

Provides critical safety information for using the operating unit in potentially explosive environments.

Operating Unit Modes and Functions

Explains manual mode operations like resetting, displaying totalizer, and flow rate.

Filling Process Control

Instructions on entering filling volume, starting, and interrupting the filling process.

Filling Process Correction and Stopping

Details how to correct and stop the filling process, including volume adjustments.

Comparative Measurement Calibration

Step-by-step guide for calibrating the flow meter by comparing displayed and actual volumes.

Automatic Mode Correction Factor Calculation

Provides the formula and steps for calculating a new correction factor in automatic mode.

Battery Replacement and Maintenance

Provides instructions for changing batteries, including safety precautions for hazardous areas.

Relay Module and Mains Unit Integration

Relay Module Fuse Replacement

Instructions for changing fuses in relay modules and mains units, including safety warnings.

Ex-RM1 m Relay Module Specifications

Ex-RM1 m Fuse Maintenance

Instructions for changing fuses in the Ex-RM1m module, including safety precautions.

Flow Meter Troubleshooting

Lutz ST Specifications

General IconGeneral
BrandLutz
ModelST
CategoryMeasuring Instruments
LanguageEnglish