3.2.10 System protection through detection of faults
The filling process can be controlled automatically by the flow meter, since faults may develop in the connecting
lines, such as running dry, blockages, defective solenoid valves, etc.
When the START key is pressed, the flow meter monitors the time during which no liquid is registered. The flow
meter switches off when a certain time limit is exceeded. STOP appears on the display. The interruped filling
process can be resumed by pressing START again when the fault has been remedied.
The monitoring time can be freely selected between 1 and 999 seconds. A time of 3 seconds is set by the
manufacturer. The monitoring function is deactivated by entering 0.
+ The monitoring time can only be changed in manual mode.
Operation Display
Enter the monitoring time, e.g. 5 seconds
(enter 0 to deactivate the function)