AT#HFLW=option
option
0: disable flow control
1: enable flow control
exec :
AT#HFLW=1
OK
state :
AT#HFLW?
#HFLW: 1
OK
info :
AT#HFLW=?
ERROR
4.3 AT#SETRTC
Set (or stop) the real time clock
ALLOWED: exec-state-info
AT#SETRTC=(op),(value1),(value2),(value3)
op:
0 = enter time, (value1,value2,value3) = (hh:mm:ss)
1 = enter date, (value1,value2,value3) = (YY:MM:DD)
2 = stop the RTC clock
exec :
AT#SETRTC=1,18,03,05
OK
state :
AT#SETRTC?
ERROR
info :
AT#SETRTC=?
#SETRTC: (0-2),((0-23)/(0-99)),((0-59)/(1-12)),((0-59)/(1-31))