6.9 AT#AUOPT
Optional parameters for AUTOTCP/AUTOUDP connection
ALLOWED: exec-state-info
Note:
– Option 2 depends upon the availability of the server mode
– Some options are not yet implemented, and will be implemented stage by stage. Therefore, ERROR may be
returned for some of the options
AT#AUOPT=(option),(value),(string)
– option:
• 1: Connection idle period
• 2: Server idle
• 3: Connection period
• 4: Connection prefix (only sent upon first connection)
• 5: Heartbeat packet
• 6: Serial prefix
– value:
• for option 1 : 0-43200. Duration of connection without data transfer, in seconds; 0 disables the feature
• for option 2 : 0-43200. Duration of SERVER without a connected remote client, in seconds; 0 disables the
feature
• for option 3 : 0-43200. Duration of connection, in seconds; 0 disables the feature
• for option 4 : 0 to disable; 1 to enable connection prefix; 2 to edit the string to be sent
• for option 5 : 0-180. Period of inactivity after which the heartbeat packet is sent, in seconds
• for option 6: 0 to disable, 1 to enable (and hex byte follows as the next parameter)
– string:
• hexadecimal string (e.g. 0AFF) required. One byte for option 6; and up to 16 bytes for option 4
exec :
AT#AUOPT=1,3600
OK
AT#AUOPT=4,2,"4149"
OK
state :
AT#AUOPT?
#AUOPT: 1,3600
#AUOPT: 2,0
#AUOPT: 3,0
#AUOPT: 4,0,"4149"
#AUOPT: 5,0
#AUOPT: 6,0,"01
OK
info :
AT#AUOPT=?
OK
Confidential, the whole document is the sole property of Maestro Wireless Solutions Ltd.
Please contact us on support.maestro-wireless.com