for mode = "AN" : voltage in mV or current in mA (which one depends on AT#VAMODE)
exec :
AT#RDIO=1
#RDIO: 1,"AN",35
OK
state :
AT#RDIO?
ERROR
info :
AT#RDIO=?
#RDIO: (1-2)
OK
4.8 AT#OPSET
To control versatile I/O in output mode
ALLOWED: exec-info
Note:
On Power up the device output state will be reset.
Before setting the output value, the channel need to be configured as digital output first
AT#OPSET=(channel),(status)
channel: 1 or 2
status: 0 or 1
exec :
AT#OPSET=1,1
OK
state :
AT#OPSET?
ERROR
info :
AT#OPSET=?
#OPSET: (1-2),(0-1)
OK
Confidential, the whole document is the sole property of Maestro Wireless Solutions Ltd.
Please contact us on support.maestro-wireless.com
21