IMPULSE•T Instruction Manual – October 2015
5-7
Motor Rotation Change
This parameter allows you to change the motor direction without changing the motor leads.
Table 5-6:Motor Rotation Parameter Settings
Acceleration/Deceleration
Acceleration time sets the time necessary for the output frequency to accelerate from 0 Hz to
maximum output frequency (E1-04). Deceleration time sets the time necessary for the output
frequency to decelerate from the maximum output frequency (E1-04) to 0 Hz.
Table 5-7:Acceleration/Deceleration Parameter Settings
Parameter
Code
Name Function Range
Initial
Value
Access
Level
B3-04 Reverse Oper Reverse motor direction 00, 01 00 Adv
00 Normal Rotation
01 Exchange Phases
Parameter
Code
Name Function Range
Initial
Value
Access
Level
B5-01 Accel Time Sets acceleration time. 0.0–25.5
sec
5.0 Adv
B5-02 Decel Time Sets deceleration time. 0.0–25.5
sec
5.0 Adv