External Fault Response Selection
It is sometimes desirable to have at least one external fault input to the drive. To properly program a
multi-function input (H1-01 to H1-05), an external fault response must be selected. The table below
shows the possible selections for an external fault response.
Table 5-17:External Fault Response Selection
(1) N.O. = normally open contact; N.C. = normally closed contact
External Fault Selection
Input Level
Selection
Detection Method External Fault Action
MFI Setting
Result
N.O.
(1)
N.C.
(1)
Always
During
Run
Ramp to
Stop
Coast to Stop
Alarm
Only
 20
 24
 28
 2C
 22
26
 2A
 2E
 21
 25
 29
 2D
 23
 27
 2B
 2F