74
Error
Code
Details of Error code Display Coping strategies
39
Connection to DPMS timed out
whenrmwaresuchasSubCPU,
DSP, FPGA, and PLD was rewritten.
C o n n e c t i o n f a i l
3 9
Check the network connection.
Carry out the update in an environment
that has little network load.
3A
Error (NG) message was received
whenrmwarewasdownloadedor
Main CPU was rewritten.
D o w n l o a d f a i l
3 A
Turn off and on the power. Updating
starts automatically.
Carry out the update in an environment
that has little network load.
3B
Error (line congestion) message
receivedwhenrmwarewas
downloaded or Main CPU was
rewritten.
D o w n l o a d f a i l
3 B
Turn off and on the power. Updating
starts automatically.
Carry out the update in an environment
that has little network load.
3C
Error (connection failure) message
receivedwhenrmwarewas
downloaded or Main CPU was
rewritten.
D o w n l o a d f a i l
3 C
Turn off and on the power. Updating
starts automatically.
Carry out the update in an environment
that has little network load.
3D
Failure to acquire (Boot Loader
Mode) IP address before rewriting
DM860A (AutoIP).
C o n n e c t i o n f a i l
3 D
Check the network connection.
Carry out the update in an environment
that has little network load.
3E
Failure to acquire (Boot Loader
Mode) IP address before rewriting
DM860A (when timed out).
C o n n e c t i o n f a i l
3 E
Check the network connection.
Carry out the update in an environment
that has little network load
3F
Mode change failure of DM860A.
C o n n e c t i o n f a i l
3 F
Reset and update again.
50
Log-in to DPMS failed when
rmwaresuchasSubCPU,DSP
and PLD was rewritten.
S u b * * * m i n
L o g i n f a i l e d 5 0
Carry out the update in an environment
that has little network load.
51
Line, etc., is busy when log-in into
DPMSwhenrmwaresuchasSub
CPU, DSP and PLD was rewritten.
S u b * * * m i n
S e r v e r i s b u s y 5 1
Carry out the update in an environment
that has little network load.
52
Connection to DPMS failed when
rmwaresuchasSubCPU,DSP
and PLD was rewritten.
S u b * * * m i n
C o n n e c t i o n F a i l 5 2
Check the network connection.
Carry out the update in an environment
that has little network load.
54
Error message received regarding
rmwaredataafterthelog-intoDPMS
whenrmwaresuchasSubCPU,DSP
and PLD was rewritten.
S u b * * * m i n
U p d a t i n g f a i l 5 4
Turn off and on the power. Updating
starts automatically.
Carry out the update in an environment
that has little network load.
55
WhenrmwaresuchasSubCPU,
DSP and PLD, request was made for
rmwaredataafterthelog-intoDPMS,
but it timed out was rewritten.
S u b * * * m i n
U p d a t i n g f a i l 5 5
Turn off and on the power. Updating
starts automatically.
Carry out the update in an environment
that has little network load.
56
Downloadingrmwarefailedafter
thelog-intoDPMSwhenrmware
such as Sub CPU, DSP and PLD
was rewritten.
S u b * * * m i n
D o w n l o a d f a i l 5 6
Turn off and on the power. Updating
starts automatically.
Carry out the update in an environment
that has little network load.
57
Firmware download error received (line
congestion) after the log-in to DPMS when
rewritingrmwaresuchasSubCPU,DSP
and PLD was rewritten.
S u b * * * m i n
D o w n l o a d f a i l 5 7
Turn off and on the power. Updating
starts automatically.
Carry out the update in an environment
that has little network load.
58
Firmware download error was received
(connection failure) after the log-in to
DPMSwhenrmwaresuchasSubCPU,
DSP and PLD was rewritten.
S u b * * * m i n
D o w n l o a d f a i l 5 8
Turn off and on the power. Updating
starts automatically.
Carry out the update in an environment
that has little network load.
5A
NACK was received when "C"
command sent to Sub CPU, DSP
PLD etc.
S u b * * * m i n
C o n n e c t i o n F a i l 5 A
Turn off and on the power. Updating
starts automatically.