EasyManua.ls Logo

Marantz SR5008/U1B - Page 70

Marantz SR5008/U1B
160 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.8. About the error code
SeethetablebelowforerrorcodesanddetailsoffaultswhenthermwareisupdatedthroughUSBmemory.
Error
Code
Details of Error code Display Coping strategies
01
Log-in to DPMS failed.
C o n n e c t i o n F a i l
0 1
Disconnect and connect the USB
memory.
02
Line, etc., is busy when logging into
DPMS.
F i l e s N o t F o u n d
0 2
Make sure that the FirmwareFile is in
the USB memory.
03
Connection to DPMS failed.
C o n n e c t i o n F a i l
0 3
Check the supported Model name/area
for the FirmwareFile.
04
Firmwareledatawasrequested
but error message was received.
C o n n e c t i o n F a i l
0 4
Start the USB Update again.
05
Firmwareledatawasrequested
but it timed out.
C o n n e c t i o n F a i l
0 5
Start the USB Update again.
06
Firmwareledatawasrequested
but error message was received.
C o n n e c t i o n F a i l
0 6
Start the USB Update again.
07
Allrmwareledatawasrequested
but it timed out.
C o n n e c t i o n F a i l
0 7
Start the USB Update again.
08
FirmwareledataofMainCPUwas
requested but error message was
received.
C o n n e c t i o n F a i l
0 8
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the
"ON/
STANDBY (
X
)"
buttonforveseconds.
09
FirmwareledataofMainCPUwas
requested but it timed out.
C o n n e c t i o n F a i l
0 9
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the
"ON/
STANDBY (
X
)"
buttonforveseconds.
0A
Error (NG) message was received
whenrmwareofMainCPUwas
downloaded.
D o w n l o a d f a i l
0 A
Check the network connection.
Carry out the update in an
environment that has little network
load.
0B
Error (line congestion) message
wasreceivedwhenrmwareof
Main CPU was downloaded.
F i l e s N o t F o u n d
0 B
Check the network connection.
Carry out the update in an
environment that has little network
load.
0D
Received Package Version is
wrong.
C o n n e c t i o n F a i l
1 0
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the
"ON/
STANDBY (
X
)"
buttonforveseconds.
10
MainCPUfailedtoreceivermware
for rewriting sent from
DM860A (when timed out).
M a i n 1 0
U p d a t i n g
f a i l e d
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the
"ON/
STANDBY (
X
)"
buttonforveseconds.
11
MainCPUfailedtoreceivermware
for rewriting sent from DM860A
(when an error occurred).
M a i n 1 1
U p d a t i n g
f a i l e d
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the
"ON/
STANDBY (
X
)"
buttonforveseconds.
12
There was invalid data in the
rmwareforrewritingsentfrom
DM860A to Main CPU (when a
Check Sum error occurred).
M a i n 1 2
U p d a t i n g
f a i l e d
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the
"ON/
STANDBY (
X
)"
buttonforveseconds.
13
The deletion of block data failed
before Main CPU was rewritten.
M a i n 1 3
E r a s e
f a i l e d
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the
"ON/
STANDBY (
X
)"
buttonforveseconds.
70
www.audiodna.sk

Table of Contents

Related product manuals