3.8. About the error code
SeethetablebelowforerrorcodesanddetailsoffaultswhenthermwareisupdatedthroughUSBmemory.
Error
Code
Details of Error code Display Coping strategies
01
Log-in to DPMS failed.
C o n n e c t i o n F a i l
0 1
Disconnect and connect the USB
memory.
02
Line, etc., is busy when logging into
DPMS.
F i l e s N o t F o u n d
0 2
Make sure that the FirmwareFile is in
the USB memory.
03
Connection to DPMS failed.
C o n n e c t i o n F a i l
0 3
Check the supported Model name/area
for the FirmwareFile.
04
Firmwareledatawasrequested
but error message was received.
C o n n e c t i o n F a i l
0 4
Start the USB Update again.
05
Firmwareledatawasrequested
but it timed out.
C o n n e c t i o n F a i l
0 5
Start the USB Update again.
06
Firmwareledatawasrequested
but error message was received.
C o n n e c t i o n F a i l
0 6
Start the USB Update again.
07
Allrmwareledatawasrequested
but it timed out.
C o n n e c t i o n F a i l
0 7
Start the USB Update again.
08
FirmwareledataofMainCPUwas
requested but error message was
received.
C o n n e c t i o n F a i l
0 8
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the
"ON/
STANDBY (
X
)"
buttonforveseconds.
09
FirmwareledataofMainCPUwas
requested but it timed out.
C o n n e c t i o n F a i l
0 9
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the
"ON/
STANDBY (
X
)"
buttonforveseconds.
0A
Error (NG) message was received
whenrmwareofMainCPUwas
downloaded.
D o w n l o a d f a i l
0 A
Check the network connection.
Carry out the update in an
environment that has little network
load.
0B
Error (line congestion) message
wasreceivedwhenrmwareof
Main CPU was downloaded.
F i l e s N o t F o u n d
0 B
Check the network connection.
Carry out the update in an
environment that has little network
load.
0D
Received Package Version is
wrong.
C o n n e c t i o n F a i l
1 0
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the
"ON/
STANDBY (
X
)"
buttonforveseconds.
10
MainCPUfailedtoreceivermware
for rewriting sent from
DM860A (when timed out).
M a i n 1 0
U p d a t i n g
f a i l e d
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the
"ON/
STANDBY (
X
)"
buttonforveseconds.
11
MainCPUfailedtoreceivermware
for rewriting sent from DM860A
(when an error occurred).
M a i n 1 1
U p d a t i n g
f a i l e d
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the
"ON/
STANDBY (
X
)"
buttonforveseconds.
12
There was invalid data in the
rmwareforrewritingsentfrom
DM860A to Main CPU (when a
Check Sum error occurred).
M a i n 1 2
U p d a t i n g
f a i l e d
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the
"ON/
STANDBY (
X
)"
buttonforveseconds.
13
The deletion of block data failed
before Main CPU was rewritten.
M a i n 1 3
E r a s e
f a i l e d
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the
"ON/
STANDBY (
X
)"
buttonforveseconds.
70