204
Appendix
TipsPlaybackConnections
Contents
Front panel Display Rear panel IndexRemote
Settings
2 Lch Level
Adjust the left channel output level.
–12dB – +12dB (Default : 0dB)
2 Rch Level
Adjust the right channel output level.
–12dB – +12dB (Default : 0dB)
2 Channel
Set whether to playback in stereo or monaural.
Stereo (Default) : Stereo playback.
Mono : Monaural playback.
%
•When “Assign Mode” (vpage192) is set to “5.1ch + ZONE2/3”, the
“Channel” setting is automatically set to “Mono”.
2 HDMI Audio (ZONE2 only)
Selects the audio signal format for playing an HDMI source in ZONE2.
Through (Default) : The HDMI audio signal is passed through the AV
receiver to the device in ZONE2.
PCM : The HDMI audio signal input into this unit is converted to a PCM
signal that can be output from the ZONE2 PRE OUT terminals
or speaker terminals.
2 Volume Level
Set the volume output level.
Variable (Default) : Volume can be adjusted.
1 – 98 (–79dB – 18dB) : Volume is fixed at the desired level. The
volume cannot be adjusting using the remote
control unit.
2 Volume Limit
Make a setting for maximum volume.
60 (–20dB) / 70 (–10dB) / 80 (0dB) (Default : 70 (–10dB))
O : Do not set a maximum volume.
%
•This can be set when “Volume Level” is set to “Variable”.
2 Power On Volume
Define the volume setting that is active when the power is turned on.
Last (Default) : Use the memorized setting from the last session.
Mute : Always mute when power is turned on.
1 – 98 (–79dB – 18dB) : The volume is adjusted to the set level.
%
•This can be set when “Volume Level” is set to “Variable”.