6.3 CONECTING TO THE MACHINE CNC
CONNECTING THE RECEIVER
Figure 6-3. ORI receiver & Cable - Connector
ELETTRICAL CONNECTIONS
Cable sheath PUR
Cable size
L= 10m – ø = 4.8 mm
Inputs Opto-isolated, 15-30V, 0,5 mA max
Outputs 3 outputs with SSR 48V, 20mA max
WARNING
All the conductors that exit the device are isolated from one another, and from the chassis, however, in
order to ensure the maximum immunity from electrical noise, whenever possible one of the power supply
connectors, preferably the negati
ve, should be connected securely to the cable braid, which in turn should
be connected to the machine chassis. If it is necessary to maintain the isolation between both conductors
and the frame, a good quality 1µF capacitor with a working voltage of at lea
st 50 V should be connected
the braid and the negative conductor.